H1 Series UV-LED Handlamps
NEXT GENERATION UV LED SOURCES - extra reliable for secure fluorescent NDT and Aerospace inspection
Choose the perfect UV LED for your specific application with our H1 & H2 Series!
- 50+ UV-A LED Handlamps
- 25+ stationary UV LED blacklights
- 10+ splashproof UV LED lamps
- 5+ waterproof UV LED lamp
- 48+ models ASTM E-3022 qualified
- 86+ models EN ISO 3059 qualified
- 18+ models Airbus AITM 6-1001 (issue 11) qualified
- 25+ models Rolls-Royce RRES 90061qualified
- 80+ models 100+ models conform to EN ISO 3059-12, Pratt & Whitney and The Boeing Company, further Aerospace and major non-destructive testing (NDT) requirements
- Ready for NADCAP / NUCAP cheklist AC 7114/1 and AC 7114/2
- mains powered, battery powered handlamp and stationary lamp available for all standards above
- numberless customes solutions
H1 Handlamp Series: with 3 sub series aand 48 models the perfect UV LED handamp for every specific application
GROUNDBREAKING INNOVATIONS
and integrated features for cost and time efficient work
EXTREMELY UNIFORM BEAM
also in very short minimum working distance for clear view and oberservation
- NO blind spots, NO cloudiness, NO tiny variations, NO structured textures (scratchy variation), NO splashy fragments in the surrounding area.
- Open the Beam Comparison of the UVE365 Handlamps and Common Simple UV LED Lamps (click here).
LARGE MAIN BEAM (< 1.200 µW/cm²)
with large soft dropping surrounding area (< 100 µw/cm²) for optimal easy detection and full orientation
- Perfect substitute for 100 W Mercury (Hg) Vapour Lamps, 35 W Xenon (MPXL) and 400 W Metal Halide Bulb based HID UV Sources, without any compromises
GROUNDBREAKING WHITE LIGHT
for uninterrupted observation while adding or fading to white light WHITHOUT flash-blinding the eyes
- adjustable white light output
- white light in addition to UV (UV and White light together)
- white light toggling (white light only)
- automatic soft dimming of the white light when pushing the button
- automatic crossfade between UV and white light
- whit light hold
- high qualitiy of white light (Ra ≥ 90, 5.000 or 5.700 Kelvin)
MAXIMUM PROCESS SECURITY
for inspection, at more secure and stable as when using Mercury Vapour lamps
- auto shut-off when single UV LED elements fail (monitoring of single UV LED elements)
- auto shut-off if battery gets low (without additional intensity drop)
- continiuous system helath monitoring
- electronic cooling monitoring
- electronic fan controlling
- acoustical, optical and vibrating signalization
ADAPTION TIME SIGNALIZATION
to ensure always proper eye adaptation and audit security
- user-adjustable timer (1, 3 or 5 minutes)
- integrated in the blue (non yellow or greenish) signal LED
ECO MODE
auto switch-off and on feature safe for maximum life-time and energy saving
- for cost efficient usage of UV LED technology and minimization of TCO (total costs of ownership)
Our highly qualified specialists and scientists will be happy to assist you in answering your questions and improving the quality of your work.
Make an inquiry now!
H1 - the revolutionary UV-handlamp-series for all industrial applications
H1: the revolutionary UV-LED-handlamp
maximal security – no flash blinding eyes
H1 is the multifunctional, high-quality and robust UV-light-series for all industrial UV-applications.
The professional lighting system is fully developed in Germany and manufactured at SECU-CHEK.
The wide range of UV-LED-handlamps enables optimal lighting for your specific application.
Do not hesitate to contact us!
Choose the perfect UV-LED-light for your application from 48 models.
3 series
|
High-performance UV LED light for demanding industrial applications With enhanced system monitoring for maximum process security as well Optimal evaluation and evaluation by means of white light which can be dimmed and superimposed |
|
Standard lamp for industrial applications, Optional with adjustable, reversible white light, with dimming just in time. |
|
Simple equipment for standard applications, Optional with adjustable, reversible white light |
3 to 6 UV-high performance-LEDs
2 beam size patterns: area radiation or focussed
optional white light functions
General overview |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Typical applications: | ALL application areas, preferably demanding time applications with increased demands on process safety in the aviation industry, in engine overhaul and the automotive industry | fluorescent, non-destructive magnetic particle testing, penetrant crack detection in industrial use, cleanroom inspections | leak detection, curing, drying, NDT-inspections, even in continuous use |
Models: | H1-09 (3 UV-LEDs) | H1-09 (3 UV-LEDs) | H1-09 (3 UV-LEDs) |
H1-12 (4 UV-LEDs) | H1-12 (4 UV-LEDs) | H1-12 (4 UV-LEDs) | |
H1-15 (5 UV-LEDs) | H1-15 (5 UV-LEDs) | H1-15 (5 UV-LEDs) | |
H1-18 (6 UV-LEDs) | H1-18 (6 UV-LEDs) | H1-18 (6 UV-LEDs) | |
Beam pattern: | Flood lamp or focussed spot |
Flood lamp or focussed spot |
Flood lamp or focussed spot |
Optional white light features: | Automatically dimmable and superimposed white light, Whose maximum brightness can be adjusted during operation |
Switchable white light, which can be dimmed during operation | switchable and pre-adjustable white light output |
Specifications and functions of UV-radiation | |||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Wavelength-peak: | 365 nm (±5 nm) | 365 nm (±5 nm) | 365 nm (±5 nm) |
Wavelength-Peak securely ensured always during operation | ● | ● | ● |
Electronic monitoring of UV-LEDs | ● | – | – |
Full width half maximum: | ≤ 18 nm | ≤ 18 nm | ≤ 20 nm |
Constant operation LEDs (no pulses) | ● | ● | ● |
Ripple of the UV radiation: | ≤ 3 % | ≤ 3 % | ≤ 5 % |
Numbers of UV-LEDs: | 3, 4, 5 or 6* | 3, 4, 5 or 6* | 3, 4, 5 or 6* |
Amount of visible light: | ≤ 5 Lux | ≤ 5 Lux |
≤ 16 Lux |
Integrated UV-passfilter: | ● | ● | optional |
Typical lifetime T50: | ≥ 18.000 hours | ≥ 15.000 hours | ≥ 12.500 hours |
Typical lifetime T70: | ≥ 15.000 hours | ≥ 12.500 hours | ≥ 10.000 hours |
Functions for advanced process- and operational safety |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Automatic shutdown and reactivation (eco-mode), switchable |
● | – | – |
Safety switch off at low battery with time delay |
● | ● | ● |
Safety switch off at low battery with prewarning |
● | – | – |
Automatic adaption time signalization (1 minute) | ● | ● | ● |
Adjustable adaption time signalization (1, 3 or 5 minutes) |
● | – | – |
Custom lamp configuration by user | ● | – | – |
Exchangeable rubber bumper with integrated protective sheave | ● | ● | ● |
UV-intensity and illumination area | |||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
UV-A-Intensity in 15 inch (38cm) distance: | 1.500 – 15.000 µW/cm² * (15 – 150 W/m²)* |
1.500 – 15.000 µW/cm² * (15 – 150 W/m²)* |
1.200 – 12.000 µW/cm² * (12 – 120 W/m²)* |
Irradiated area > 1.000 µW / cm² in 15 inch (38 cm): |
ø 13 up to 25 cm* | ø 13 up to 25 cm* | ø 10 up to 21 cm* |
Irradiated area > 100 µW / cm² in 15 inch (38 cm): |
ø 25 up to 52 cm* | ø 25 up to 52 cm* | ø 25 up to 52 cm* |
Stability of UV-intensity: | ≥ 85 – 95 %* | ≥ 85 – 95 %* | ≥ 80 – 90 %* |
Risk class according to DGZfP EM6: | 2* (for Intensities > 80 W/m²: 3) |
2* (for Intensities > 80 W/m²: 3) |
2* (for Intensities > 80 W/m²: 3) |
State signaling |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Blue signal-LED for UV-radiation | ● | ● | ● |
No irritating yellow or green control-LEDs at UV-operation | ● | ● | ● |
Multicolored control-LED | ● | ● | ● |
Separate control-LED for UV and white light | ● | ● | – |
Acoustic signal | ● | ● | ● |
Tactile vibration signal | ● | – | – |
Fast, safe and easy status display in the user’s view | ● | ● | ● |
Possible qualifications, approvals and fulfilling requirements |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Guaranteed requalification possibility for upcoming DIN, EN, ISO and ASTM standards | ● | ● | – |
Qualified ambient temperature range | 5 – 50° C | 5 – 50° C | 5 – 40° C |
Detailed certificate and test report | ● | ● | – |
DIN EN ISO 3059: 2013-3 (Conditions of observation) | ● | ● | ● |
DIN EN ISO 9934: 2013-05 (Magnetic powder test) | ● | ● | ● |
DIN EN ISO 3452: 2014 (Penetration test) | ● | ● | ● |
ASTM E-2297-04 (2010) (Guide for magnetic powder testing and penetration testing) | ● | ● | ● |
ASTM E-3022 (UV-LED-lamps) | ●* | ●* | ●* |
ASTM E-1444 M-12 (Magnetic powder test) | ● | ● | ● |
ASTM E-1417 M-13 (Penetration test) | ● | ● | ● |
Rolls-Royce RRES 90061 (Qualification of UV LED lights) |
●* | ●* | ●* |
MTU Aero Engines | ● | ● | ● |
Safran Groupe (SNECMA, Turbomeca) | no request available | no request available | no request available |
Airbus AITM6-1001 (Penetration test) | ● | ● | ● |
Pratt & Whittney SPM (PN 585005) (Penetration test) | ● | ● | ● |
ASME-Code (BPVS) (Magnetic powder and penetrant testing) | ● | ● | ● |
NADCAP (Aviation auditing) | no request available | no request available | no request available |
Boeing | no request available | no request available | no request available |
General Electric Aviation (GE) | no request available | no request available | no request available |
Controls, external control and integration in plants | |||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Integrated touch switch | 1 / 5* | 1 / 5* | 1 / 2* |
Comfortable one-hand operation of the white light functions | ● | ● | ● |
HOLD function for fixing the white light condition | ● | ● | – |
Connection possibility for external control of the white light, e.g. by foot switch | ● | – | – |
Connection for external foot dimmer | ● | – | – |
Control of the luminaire via external machine control (for example PLC of the test bench) | ● | – | – |
Feedback of the operating state to external control, triggering of external alarms in case of fault or logging by PLC | ● | – | – |
Direct switching on of the luminaire can be adjusted with voltage supply | ● | – | – |
Integrated appliances for standard fixtures |
● | ● | ● |
Functions and specifications of optional, integrated white light |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Preset white light brightness | ● | ● | ● |
White light brightness can be changed during operation | ● | ● | – |
Changeover Between UV radiation and white light |
● | ● | ● |
Integration of white light with UV radiation | ● | ● | – |
Automatic adjustment of white light to UV radiation |
● | – | – |
Automatic cross-fading between UV radiation and white light |
● | – | – |
Variety of white light with relapse option during operation | ● | – | – |
Uniform, flat, blinding illumination | ● | ● | ● |
Illuminance (Lux) In 38cm distance |
up to 5.000 lux* | up to 5.000 lux* | up to 1.500 lux* |
Color temperature | 5.300 K – 6.500 K | 5.300 K – 6.500 K | 5.300 K – 6.500 K |
Color rendering index (Ra) | ≥ 90 | ≥ 90 | ≥ 70 |
Electrical specifications |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Type of power supply: | External power supply (AC / DC) or External rechargeable battery (LiIon or NiMH) |
External power supply (AC / DC) or External rechargeable battery (LiIon or NiMH) |
External power supply (AC / DC) or External rechargeable battery (LiIon or NiMH) |
Power consumption: | 15 W – 50 W* | 15 W – 50 W* | 15 W – 25 W* |
Max. Operating voltage Handset: | 50 V DC | 50 V DC | 50 V DC |
Protective low voltage on handset: (≤ 60 VDC) | yes | yes | yes |
Protection class: | IP 20 with protected electronics | IP 20 with protected electronics | IP 20 with protected electronics |
Protection class: | III (Protective low voltage) | III (Protective low voltage) | III (Protective low voltage) |
Technical specifications | |||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Dimensions: | 160 x 105 x 95 mm ( 6,3 x 4,1 x 3,7 inch) |
160 x 105 x 95 mm ( 6,3 x 4,1 x 3,7 inch) |
160 x 105 x 95 mm ( 6,3 x 4,1 x 3,7 inch) |
Weight of lamp head: | 0,70 kg – 0,85 kg* | 0,70 kg – 0,85 kg* | 0,70 kg – 0,85 kg* |
Active air cooling for maximum service life and safe operation | ● | ● | ● |
Electronic monitoring of the fan | ● | ● | ● |
Safety shutdown at overtemperature | ● | ● | ● |
Extra quiet, temperature controlled fan controller | ● | – | – |
Operating conditions |
|||
Series: | UVE 365 H1 | UVN 365 H1 | UVS 365 H1 |
Humidity in %: | 20- 80 % (not condensing) | 20- 80 % (not condensing) | 20- 80 % (not condensing) |
Permissible ambient temperature: | 5 – 50° C | 5 – 50° C | 5 -40° C |
We reserve the right at any time to make technical modifications without announcement.
*: depend on model
Accessoires
Engineered and Made in Germany
by NDT Experts for NDT Professionals
To schedule a product demo or request further product information, please fill in your contact details.
We look forward to your inquiry!
You are also welcome to contact us by phone or email.
Direct contact:
SECU-CHEK GmbH
An der Fähre 9
66271 Kleinblittersdorf
GERMANY
Phone +49 6805-942859-0
Fax +49 6805-942859-95