Model overview
|
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
typical areas of application: |
ALL applications, preferably demanding long-term applications with increased requirements for process reliability in the aviation industry, in engine overhaul and in the automotive industry |
fluorescent, non-destructive magnetic powder testing, penetration crack testing in continuous industrial use, cleanroom inspections |
Leak detection, curing, drying, ZfP inspections, also in continuous use |
ALL applications, preferably demanding long-term applications with increased requirements for process reliability in the aviation industry, in engine overhaul and in the automotive industry |
|
|
Variants: |
H1-09 (3 UV-LEDs) |
H1-09 (3 UV-LEDs) |
H1-09 (3 UV-LEDs) |
H2-24 (8 UV-LEDs) |
3 – 4 UV-LEDs |
|
H1-12 (4 UV-LEDs) |
H1-12 (4 UV-LEDs) |
H1-12 (4 UV-LEDs) |
|
H1-15 (5 UV-LEDs) |
H1-15 (5 UV-LEDs) |
H1-15 (5 UV-LEDs) |
|
H1-18 (6 UV-LEDs) |
H1-18 (6 UV-LEDs) |
H1-18 (6 UV-LEDs) |
|
Illumination: |
Floodlamp or
focused illumination |
Floodlamp or
focused illumination |
Floodlamp or
focused illumination |
Floodlamp or
focused illumination |
Floodlamp or
focused illumination |
|
Optional white light functions: |
automatic shiftable and dimmable white-light
whose maximum brightness can be set during operation |
switchable white light that can be dimmed during operation |
shiftable and
pre-adjustable white light |
automatic shiftable and dimmable white-light
whose maximum brightness can be set during operation |
No information |
|
Specification and functions UV radiation |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Peak-Wavelength: |
365 nm (±5 nm) |
365 nm (±5 nm) |
365 nm (±5 nm) |
365 nm (±5 nm) |
365 nm (±5 nm) |
Guaranteed peak wavelength during operation within the qualified ambient temperature |
● |
● |
● |
● |
● |
Electronic Monitoring of the UV-LEDs |
● |
– |
– |
● |
– |
FWHM (Full Width Half Maximum): |
≤ 18 nm |
≤ 18 nm |
≤ 20 nm |
≤ 18 nm |
|
Constant operation of the LEDs (no pulses) |
● |
● |
● |
● |
|
Residual ripple of UV radiation: |
≤ 3 % |
≤ 3 % |
≤ 5 % |
≤ 3 % |
|
Number of UV LEDs: |
3, 4, 5 or 6* |
3, 4, 5 or 6* |
3, 4, 5 or 6* |
8 |
2 – 4 |
Proportion of white light
(measured at minimum working distance): |
≤ 5 Lux |
≤ 5 Lux |
≤ 16 Lux |
≤ 5 Lux |
5 Lux |
Integrated UV-passfilter |
● |
● |
optional |
● |
No information |
Typical lifespan T50: |
≥ 18.000 hours |
≥ 15.000 hours |
≥ 12.500 hours |
≥ 18.000 hours |
10.000 hours |
Typical lifespan T70: |
≥ 15.000 hours |
≥ 12.500 hours |
≥ 10.000 hours |
≥ 15.000 hours |
5.000 hours |
|
Features for advanced process and operational reliability |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Automatic shutdown and reactivation (eco-mode), switchable
|
● |
– |
– |
● |
No information |
Safety switch off at low battery with time delay |
● |
● |
● |
● |
No information |
Safety switch off at low battery with prewarning |
● |
– |
– |
● |
No information |
Automatic adaption time signalization (1 minute) |
● |
● |
● |
● |
No information |
Adjustable adaption time signalization
(1, 3 or 5 minutes)
|
● |
– |
– |
● |
No information |
Custom lamp configuration by user |
● |
– |
– |
● |
No information |
Exchangeable rubber bumper with integrated protective sheave |
● |
● |
● |
● |
No information |
|
UV-intensity and illumination area |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
UV-A-Intensity in 15 inch (38cm) distance: |
1.500 – 15.000 µW/cm² *
(15 – 150 W/m²)* |
1.500 – 15.000 µW/cm² *
(15 – 150 W/m²)* |
1.200 – 12.000 µW/cm² *
(12 – 120 W/m²)* |
1.500 – 15.000 µW/cm² *
(15 – 150 W/m²)* |
~2.450 in 16 inch (40cm) distance |
Irradiated area
> 1.000 µW / cm² in 15 inch (38 cm): |
ø 13 up to 25 cm* |
ø 13 up to 25 cm* |
ø 10 up to 21 cm* |
ø 13 up to 25 cm* |
ø 20 cm |
Irradiated area
> 100 µW / cm² in 15inch (38 cm): |
ø 25 up to 52 cm* |
ø 25 up to 52 cm* |
ø 25 up to 52 cm* |
ø 25 up to 52 cm* |
ø 40 cm |
Stability of UV-intensity: |
≥ 85 – 95 %* |
≥ 85 – 95 %* |
≥ 80 – 90 %* |
≥ 85 – 95 %* |
No information |
Risk class according to DGZfP EM6
(classification on occupational safety): |
2*
(for Intensities > 80 W/m²: 3) |
2*
(for Intensities > 80 W/m²: 3) |
2*
(for Intensities > 80 W/m²: 3) |
2*
(for Intensities > 80 W/m²: 3) |
2 |
|
State signaling |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Blue signal-LED for UV-radiation |
● |
● |
● |
● |
No information |
No irritating yellow or green control-LEDs at UV-operation |
● |
● |
● |
● |
No information |
Multicolored control-LED |
● |
● |
● |
● |
No information |
Separate control-LED for UV and white light |
● |
● |
– |
● |
No information |
Acoustic signal |
● |
● |
● |
● |
No information |
Tactile vibration signal |
● |
– |
– |
● |
No information |
Fast, safe and easy status display in the user’s view |
● |
● |
● |
● |
No information |
|
Possible qualifications, approvals and fulfilling requirements |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Guaranteed requalification possibility for upcoming DIN, EN, ISO and ASTM standards |
● |
● |
– |
● |
No information |
Qualified ambient temperature range |
5 – 50° C |
5 – 50° C |
5 – 40° C |
5 – 50° C |
10 – 35° C |
Detailed certificate and test report |
● |
● |
– |
● |
No information |
DIN EN ISO 3059: 2013-3 (Conditions of observation) |
● |
● |
● |
● |
No information |
DIN EN ISO 9934: 2013-05 (Magnetic powder test) |
● |
● |
● |
● |
No information |
DIN EN ISO 3452: 2014 (Penetration test) |
● |
● |
● |
● |
No information |
ASTM E-2297-04 (2010) (Guide for magnetic powder testing and penetration testing) |
● |
● |
● |
● |
No information |
ASTM E-3022 (UV-LED-lamps) |
●* |
●* |
●* |
●* |
No information |
ASTM E-1444 M-12 (Magnetic powder test) |
● |
● |
● |
● |
No information |
ASTM E-1417 M-13 (Penetration test) |
● |
● |
● |
● |
No information |
Rolls-Royce RRES 90061
(Qualification of UV LED lights) |
●* |
●* |
●* |
●* |
• (1 of 4 devices) |
MTU Aero Engines |
● |
● |
● |
● |
No information |
Safran Groupe (SNECMA, Turbomeca) |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
Airbus AITM6-1001 (Penetration test) |
● |
● |
● |
● |
No information |
Pratt & Whittney SPM (PN 585005) (Penetration test) |
● |
● |
● |
● |
No information |
ASME-Code (BPVS) (Magnetic powder and penetrant testing) |
● |
● |
● |
● |
No information |
NADCAP (Aviation auditing) |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
Boeing |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
General Electric Aviation (GE) |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
no requirement available |
|
Controls, external control and integration in plants |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Integrated touch switch |
1 / 5* |
1 / 5* |
1 / 2* |
|
– |
Comfortable one-hand operation of the white light functions |
● |
● |
● |
● |
– |
HOLD function for fixing the white light condition |
● |
● |
– |
● |
– |
Connection possibility for external control of the white light, e.g. by foot switch |
● |
– |
– |
● |
– |
Connection for external foot dimmer |
● |
– |
– |
● |
– |
Control of the luminaire via external machine control (for example PLC of the test bench) |
● |
– |
– |
● |
– |
Feedback of the operating state to external control, triggering of external alarms in case of fault or logging by PLC |
● |
– |
– |
● |
– |
Direct switching on of the luminaire can be adjusted with voltage supply |
● |
– |
– |
● |
– |
Integrated appliances for standard fixtures |
● |
● |
● |
● |
– |
|
Functions and specifications of optional, integrated white light |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Preset white light brightness |
● |
● |
● |
● |
|
White light brightness can be changed during operation |
● |
● |
– |
● |
– |
Changeover
Between UV radiation and white light |
● |
● |
● |
● |
• (1 of 4 devices) |
Integration of white light with UV radiation |
● |
● |
– |
● |
– |
Automatic adjustment
of white light to UV radiation
|
● |
– |
– |
● |
– |
Automatic cross-fading
Between UV radiation and white light |
● |
– |
– |
● |
– |
Variety of white light with relapse option during operation |
● |
– |
– |
● |
– |
Uniform, flat, blinding illumination |
● |
● |
● |
● |
– |
Illuminance (Lux)
In 38cm distance: |
up to 5.000 lux* |
up to 5.000 lux* |
up to 1.500 lux* |
up to 5.000 lux* |
|
Color temperature: |
5.300 K – 6.500 K |
5.300 K – 6.500 K |
5.300 K – 6.500 K |
5.300 K – 6.500 K |
|
Color rendering index (Ra): |
≥ 90 |
≥ 90 |
≥ 70 |
≥ 90 |
|
|
Electrical specifications |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Type of power supply: |
External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH) |
External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH) |
External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH) |
External power supply (AC / DC) or
External rechargeable battery (LiIon or NiMH) |
|
Power consumption: |
15 W – 50 W* |
15 W – 50 W* |
15 W – 25 W* |
15 W – 50 W* |
|
max. Operating voltage Handset: |
50 V DC |
50 V DC |
50 V DC |
50 V DC |
|
Protective low voltage on handset: (≤ 60 VDC) |
yes |
yes |
yes |
yes |
|
Protection class: |
IP 20 with protected electronics |
IP 20 with protected electronics |
IP 20 with protected electronics |
IP 20 with protected electronics |
|
Protection class: |
III (Protective low voltage) |
III (Protective low voltage) |
III (Protective low voltage) |
III (Protective low voltage) |
|
|
|
|
Technical specifications |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Dimensions: |
160 x 105 x 95 mm
( 6,3 x 4,1 x 3,7 inch) |
160 x 105 x 95 mm
( 6,3 x 4,1 x 3,7 inch) |
160 x 105 x 95 mm
( 6,3 x 4,1 x 3,7 inch) |
|
|
Weight of lamp head: |
0,70 kg – 0,85 kg* |
0,70 kg – 0,85 kg* |
0,70 kg – 0,85 kg* |
|
|
Active air cooling for maximum service life and safe operation |
● |
● |
● |
● |
|
Electronic monitoring of the fan |
● |
● |
● |
● |
No information |
Safety shutdown at overtemperature |
● |
● |
● |
● |
No information |
Extra quiet, temperature controlled fan controller |
● |
– |
– |
● |
No information |
|
Operating conditions |
Series: |
UVE 365 H1 |
UVN 365 H1 |
UVS 365 H1 |
UVE H224 |
Competition |
Humidity in %: |
20- 80 % (not condensing) |
20- 80 % (not condensing) |
20- 80 % (not condensing) |
20- 80 % (not condensing) |
No information |
Permissible ambient temperature: |
5 – 50° C |
5 – 50° C |
5 -40° C |
5 – 50° C |
10 – 35° C |